• Call Us: +44 (0)7474 124 340 +44 (0)7906 297 117
  • FIND US: Cromwell Rd, 70 PYM COURT, CB1 3FB CAMBRIDGE, UK

MB-SR50N HI

The structure presented here is a version of  MB-SR50N featuring enhanced thermal insulation performance.

The system is designed for the construction and execution of flat, light-weight curtain walls of the suspended or filling type, roofs, skylights and other structures. The shapes of profiles  enable selection of mullion and transom profiles which flush with each other on the inside surface of the façade.

The MB-SR50N HI system features basic characteristics and possibilities inherent in the base construction MB-SR50N. The thermal insulation zone deserves a particular mention, though. Here, special two-component insulators have been applied. They are based on a HPVC insulator (or a set of insulators of appropriate width), identical to the one used in the standard MB-SR50 system, which makes it possible to drive screws with high accuracy during the installation process  at the building site. On both lateral surfaces of the insulator additional elements made of flexible material are attached  (glued on), which enhance thermal insulation performance  and limit the air flow in the space separating the infills of the façade. The insulator built in this way enables maintaining  convenience and accuracy of mounting of a traditional façade, ensuring at the same time that very good thermal insulation parameters are attained – the heat transfer coefficient, depending on the applied profiles and accessories  spans between 0.94 to 1.94 W/m2K. Likewise in the base version of the façade, the structure allows for installation of different types of infills,  including  glazing of large dimensions and two-chamber insulating glazing units. With regard to active elements, the MB-70HI doors and windows featuring enhanced thermal insulation performance are particularly recommended  for façades of the HI series.

The MB-SR50N HI system was subjected  to thorough testing  performed by the Building Research and Testing Institute IFT Rosenheim and attained very high technical parameters.

  • Air infiltration: class AE 1200, EN 12152
  • Rainwater tightness: class RE1500, EN 12154
  • Resistance to wind load: 2.4 kN/m2, EN 13116:2002
  • Impact resistance: class I5/E5,  PN-EN 14019

As regards the declaration of conformity for vertical façades based on the MB-SR50N HI system, a harmonized European Standard PN-EN 13830  “Curtain Walling. Product Standard” has been applied as a reference document.